Fluke 805 Vibration Meter and 805ES Sensor Kit for Pumps, Fans and Gearbox Screening

Fluke 805 Vibration Meter and 805ES Sensor Kit for Pumps, Fans and Gearbox Screening

  • Highlight

    Fluke 805 vibration meter

    ,

    805ES sensor kit

    ,

    pump fan gearbox screening

  • Overall Vibration Range
    10 Hz To 1,000 Hz, Acceleration / Velocity / Displacement
  • Bearing Measurement
    Crest Factor+ (CF+), 4,000 Hz To 20,000 Hz, Scale 1 To 16
  • Acceleration Range
    0.01 G To 50 G, Resolution 0.01 G, Sensor Sensitivity 100 MV/g
  • IR Temperature Range
    −20 °C To 200 °C, ±2 °C, Fixed Focus At 3.8 Cm
  • Memory And Interface
    3,500 Measurements, USB 2.0, 3.5 Mm Audio, SMB External Sensor Jack
  • Environmental Rating
    IP54, 1 M Drop, 500 G Peak Vibration, −20 °C To 50 °C Operating
  • Shipping Term
    International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/Sea Freight / Air Freight / International Special Line
  • Freight Charge
    For Industrial Equipment (E.G., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/Volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quot
  • Brand Name
    Fluke
  • Model Number
    Fluke 805
  • Minimum Order Quantity
    1
  • Price
    $2000 - $3800
  • Packaging Details
    Original
  • Delivery Time
    3-5Workdays
  • Payment Terms
    L/C,D/A,D/P,T/T

Fluke 805 Vibration Meter and 805ES Sensor Kit for Pumps, Fans and Gearbox Screening

Product Highlights
  • Two measurements on one screen: overall vibration and bearing condition. Overall vibration covers 10 Hz to 1,000 Hz in acceleration, velocity or displacement; bearing condition is assessed by Crest Factor+ between 4,000 Hz and 20,000 Hz. Both are reported on the same four-level severity scale, so a technician walks up, takes one reading, and gets a go / no-go answer in both domains.
  • Crest Factor+ solves the failure mode of ordinary crest factor. Plain crest factor peaks and then falls as a bearing approaches catastrophic failure, which is precisely when you most need the number to keep rising. Fluke's CF+ algorithm runs from 1 to 16 and increases monotonically as the bearing degrades, mapped to Good / Satisfactory / Unsatisfactory / Unacceptable.
  • The sensor design is the actual engineering. Angle and contact pressure are the two biggest error sources in handheld vibration measurement, and the 805's sensor and its green/red pressure indicator are built to reduce variation from both — the display tells you when you are pressing too lightly or too hard before it lets a bad reading through.
  • No vibration analyst required. The severity scale, the pressure indicator and the on-screen prompts mean a maintenance technician with no ISO category training can execute a route and produce usable, repeatable numbers. That is the entire point of the product, and it is why it is a screening device rather than an analyser.
  • Spot infrared temperature is built in — −20 to 200 °C, ±2 °C, fixed focus at about 3.8 cm. Bearing housing temperature alongside vibration separates a lubrication problem from a mechanical one, and it costs you no extra tool.
  • Audio output for listening to bearing tones. Plug headphones into the 3.5 mm jack and hear the bearing directly. Crude, fast, and often decisive when a number sits right on a threshold.
  • 3,500 measurements on board, USB export, pre-built Excel templates. The templates include ISO 10816-1 / -3 / -7 colour bands, so the trend chart you produce is already read against a recognised standard rather than against your own guesswork.
  • Built for a plant floor, not a lab: IP54, 1 m drop, survives 500 g peak vibration. Operating range −20 to 50 °C, so it works in a cold store and beside a compressor.
  • External sensor support for hard-to-reach points via the SMB jack on top — this is what the 805ES adds, and the FAQ below explains exactly what it can and cannot measure.
  • Flashlight for reading nameplates and locating measurement points in dark plant rooms and cabinets.
Specifications
1. Variants and Accessories
Item What it is Notes
Fluke 805 Vibration meter, USB + Excel workflow The baseline instrument
Fluke 805 FC Same instrument with Fluke Connect Adds wireless measurement sharing, cloud equipment history, ShareLive video calls, TrendIt graphs. Otherwise identical
Fluke 805ES External vibration sensor Accessory, not a meter. 90° head, high-power magnet, mil-spec connector, 7 ft coiled cable
2. Vibration Measurement
Parameter Specification
Low frequency range (overall measurement) 10 Hz to 1,000 Hz
High frequency range (CF+ measurement) 4,000 Hz to 20,000 Hz
Severity levels Good, Satisfactory, Unsatisfactory, Unacceptable
CF+ scale 1 to 16, increasing as bearing condition worsens
Vibration limit 50 g peak (100 g peak-peak)
A/D converter 16-bit
Signal to noise ratio 80 dB
Sampling rate 20,000 Hz low frequency; 80,000 Hz high frequency
Sensor sensitivity 100 mV/g ±10 %
Measurement range 0.01 g to 50 g
Resolution 0.01 g
Accuracy At 100 Hz, ±5 % of measured value
Amplitude units — acceleration g, m/s²
Amplitude units — velocity in/s, mm/s
Amplitude units — displacement mils, mm
3. Infrared Temperature
Parameter Specification
Range −20 °C to 200 °C (−4 °F to 392 °F)
Accuracy ±2 °C (4 °F)
Focal length Fixed, at approximately 3.8 cm (1.5 in)
Applications
  • Route-based bearing screening on rotating equipment. Pumps, fans, motors, blowers, gearboxes with rolling element bearings, air compressors, cooling tower drives, chillers, positive displacement pumps and machine tools — the categories Fluke lists for this instrument. One reading per point, severity verdict on screen, walk on.
  • Frontline mechanical troubleshooting by non-specialists. The core value proposition: a technician who cannot interpret an FFT can still read "Unsatisfactory" and raise a work order. The tool moves the first line of condition monitoring from the reliability engineer to the maintenance team.
  • Trending against ISO 10816. Export to the supplied Excel template and the readings plot into the ISO 10816-1 / -3 / -7 colour bands. This is what turns a folder of numbers into a case for replacing a bearing before it fails.
  • Lubrication decisions. Vibration plus the spot IR temperature on the same screen distinguishes a dry bearing (rising temperature and vibration) from an imbalanced one (rising vibration, stable temperature). That distinction decides whether you grease it or schedule it.
  • Post-repair verification. Take a baseline after a bearing change and compare it against pre-failure data to confirm the repair worked, rather than assuming it did.
  • Hard-to-reach points with the 805ES. Low-frequency overall vibration inside guards or behind pipework, where the meter body will not fit.
Frequently Asked Questions
Q1. Is the 805ES a separate vibration meter?

No. It is an external vibration sensor that plugs into the 805's SMB jack on top of the instrument. Fluke lists it under accessories, and Fluke's 805 data sheet says explicitly that Fluke supports but does not provide external sensors. If you want a second meter you need a second 805.

Q2. Can the 805 tell me what the fault is — unbalance, misalignment, or a bad bearing?

It tells you how bad, not what. The 805 is a screening device: it reports overall vibration on a four-level severity scale and bearing condition by Crest Factor+ on the same scale, plus a temperature reading. It does not perform spectral analysis or identify fault frequencies. Fault identification is the job of the Fluke 810 vibration tester or a full analyser with an analyst behind it. Being clear about this is what stops a screening-tool sale from turning into a "it doesn't do what I expected" return.

Q3. Can I use the 805ES sensor to check bearings in places I can't reach?

No, and this is the mistake to pre-empt. The 805ES is specified from 0 to 6,000 cpm, that is 0 to 100 Hz. Bearing condition is derived from the 4,000 to 20,000 Hz band using the meter's direct sensor tip. The external sensor therefore covers overall low-frequency vibration only. It extends your reach, not your bearing diagnostics.

Q4. What is the difference between the 805 and the 805 FC?

The FC adds Fluke Connect: wireless transfer of measurements, cloud-backed equipment history, TrendIt graphs, AutoRecord and ShareLive video calls, all through the mobile app. The measurement engine, sensor, severity scale and accuracy are the same. If the customer's workflow is USB cable plus Excel, the plain 805 is sufficient; if they want readings off the instrument without walking back to a PC, it is the FC.

Q5. How does this compare against ISO 10816 limits?

The supplied Excel template plots your readings against the ISO 10816-1, -3 and -7 bands, which is the practical way to use the instrument for a machine population. But note the distinction: the instrument's four-level severity scale is Fluke's own screening logic, informed by a database built from thousands of machines. It is not a certified ISO 10816 evaluation, and it is not a substitute for one where a contract or an insurer requires a formal assessment.

Q6. How long does it run on a set of batteries, and what should I stock?

250 measurements on two AA alkaline cells. At thirty points a day that is roughly eight working days, so plan on a set of cells per two weeks per technician. The instrument takes alkaline cells — supply them, because a route that stops halfway is worse than a route not started.