| Item | What it is | Notes |
|---|---|---|
| Fluke 805 | Vibration meter, USB + Excel workflow | The baseline instrument |
| Fluke 805 FC | Same instrument with Fluke Connect | Adds wireless measurement sharing, cloud equipment history, ShareLive video calls, TrendIt graphs. Otherwise identical |
| Fluke 805ES | External vibration sensor | Accessory, not a meter. 90° head, high-power magnet, mil-spec connector, 7 ft coiled cable |
| Parameter | Specification |
|---|---|
| Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
| High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz |
| Severity levels | Good, Satisfactory, Unsatisfactory, Unacceptable |
| CF+ scale | 1 to 16, increasing as bearing condition worsens |
| Vibration limit | 50 g peak (100 g peak-peak) |
| A/D converter | 16-bit |
| Signal to noise ratio | 80 dB |
| Sampling rate | 20,000 Hz low frequency; 80,000 Hz high frequency |
| Sensor sensitivity | 100 mV/g ±10 % |
| Measurement range | 0.01 g to 50 g |
| Resolution | 0.01 g |
| Accuracy | At 100 Hz, ±5 % of measured value |
| Amplitude units — acceleration | g, m/s² |
| Amplitude units — velocity | in/s, mm/s |
| Amplitude units — displacement | mils, mm |
| Parameter | Specification |
|---|---|
| Range | −20 °C to 200 °C (−4 °F to 392 °F) |
| Accuracy | ±2 °C (4 °F) |
| Focal length | Fixed, at approximately 3.8 cm (1.5 in) |
No. It is an external vibration sensor that plugs into the 805's SMB jack on top of the instrument. Fluke lists it under accessories, and Fluke's 805 data sheet says explicitly that Fluke supports but does not provide external sensors. If you want a second meter you need a second 805.
It tells you how bad, not what. The 805 is a screening device: it reports overall vibration on a four-level severity scale and bearing condition by Crest Factor+ on the same scale, plus a temperature reading. It does not perform spectral analysis or identify fault frequencies. Fault identification is the job of the Fluke 810 vibration tester or a full analyser with an analyst behind it. Being clear about this is what stops a screening-tool sale from turning into a "it doesn't do what I expected" return.
No, and this is the mistake to pre-empt. The 805ES is specified from 0 to 6,000 cpm, that is 0 to 100 Hz. Bearing condition is derived from the 4,000 to 20,000 Hz band using the meter's direct sensor tip. The external sensor therefore covers overall low-frequency vibration only. It extends your reach, not your bearing diagnostics.
The FC adds Fluke Connect: wireless transfer of measurements, cloud-backed equipment history, TrendIt graphs, AutoRecord and ShareLive video calls, all through the mobile app. The measurement engine, sensor, severity scale and accuracy are the same. If the customer's workflow is USB cable plus Excel, the plain 805 is sufficient; if they want readings off the instrument without walking back to a PC, it is the FC.
The supplied Excel template plots your readings against the ISO 10816-1, -3 and -7 bands, which is the practical way to use the instrument for a machine population. But note the distinction: the instrument's four-level severity scale is Fluke's own screening logic, informed by a database built from thousands of machines. It is not a certified ISO 10816 evaluation, and it is not a substitute for one where a contract or an insurer requires a formal assessment.
250 measurements on two AA alkaline cells. At thirty points a day that is roughly eight working days, so plan on a set of cells per two weeks per technician. The instrument takes alkaline cells — supply them, because a route that stops halfway is worse than a route not started.