| Model | Universal Channels | Relay Boards | Universal Input Connectors | Total Usable Channels |
|---|---|---|---|---|
| 2638A/20 | 20 | 1 × 2638A-RLY | 1 × 2638A-100 | 22 (20 universal + 2 current) |
| 2638A/40 | 40 | 2 × 2638A-RLY | 2 × 2638A-100 | 44 |
| 2638A/60 | 60 | 3 × 2638A-RLY | 3 × 2638A-100 | 66 |
Power version must be specified at order: 100 V, 120 V, 220 V or 240 V. The setting can be changed by the user afterwards.
| Item | Specification |
|---|---|
| Rear slots | 3, each holding one relay board plus one Universal Input Connector |
| Channel expansion | 2638A-20chkit adds 20 universal channels (one 2638A-RLY board plus one 2638A-100 connector) |
| Spare connector | 2638A-100 extra Universal Input Connector |
| Spare relay board | 2638A-RLY replacement board |
| Input isolation | Differential, isolated |
| CJC | Factory-calibrated cold junction compensation inside each connector; calibration date and serial number stored in the connector |
| Relay wear monitoring | Built-in maximum relay counter per installed relay board |
| Range | Resolution at 6.5 Digits | Input Impedance |
|---|---|---|
| 100 mV | 0.1 µV | 10 MΩ or >10 GΩ |
| 1 V | 1 µV | 10 MΩ or >10 GΩ |
| 10 V | 10 µV | 10 MΩ or >10 GΩ |
| 100 V | 100 µV | 10 MΩ ±1 % |
| 300 V | 1 mV | 10 MΩ ±1 % |
The core use. Wire 20 thermocouples into one connector, run the profile, download the scan file. If you need to zero a large batch of thermocouples against a reference before a profiling run, the instrument normalises all readings to the reference channel in one action and stores the offsets in a supporting data file — which is what makes chamber tests, heat-treat cycles under AMS guidelines and 21 CFR validation work practical.
Long-duration logging of component and board temperatures plus supply voltages, with per-channel alarms to catch a single device drifting out of spec overnight. The 22-channel module is cheap enough to dedicate one per rack position.
Four-wire resistance on contacts and windings, PRT and thermistor measurement for material characterisation, and DC current on bias circuits — all on the same scan, so resistance drift and temperature drift are time-correlated rather than captured in separate runs.
SCPI over LAN, external trigger in, six TTL alarm outputs out, and 45 channels per second. Small enough to sit at a test station, programmable enough to be driven by a line controller.
Multi-point temperature mapping of ovens, furnaces, autoclaves and environmental chambers, using type K, N or R probes depending on the range, with trend charts visible on the instrument while the run is in progress.
The 6.5-digit DMM mode covers DC V, AC V, resistance and frequency on the front-panel jacks when the scan function is idle, so the unit doubles as a bench meter in a lab that cannot justify two instruments.
Both, depending on how you count. The model is named 2638A/20 because it ships with 20 universal differential inputs. The 2638A-100 Universal Input Connector that comes with it carries 22 channels: those 20 universal inputs plus 2 dedicated low-burden AC/DC current channels. With one module installed you can measure 22 signals. Add modules to the other two rear slots and you reach 66 — 60 universal plus 6 current.
The 0.0024 % headline is the 10 V DC range, one-year specification, at 23 ± 5 °C, in 6.5-digit mode, after a one-hour warm-up: ±(0.0024 % of reading + 0.0005 % of range). Outside 18–28 °C add 0.0005 % of reading + 0.0001 % of range per °C on that range. The 100 mV range is less accurate (0.0037 + 0.0035 one year) — if your measurement is in the tens of millivolts, plan around that range's number, not the headline.
Because the cold junction compensation is inside the plug-in connector, factory-calibrated, and its calibration date and serial number are stored electronically in the connector and read by the mainframe. That removes the error you normally get from CJC sitting on a multiplexer board at a different temperature from your wiring terminals, and it keeps that accuracy when you swap connectors between sites. The trade-off: the connector's own calibration date travels with it, so track it in your calibration programme.
No. The input set is DC V, AC V, DC and AC current, resistance, thermocouple, PRT, thermistor and frequency. There is no harmonic analysis, no power quality event capture, no IEC 61000-4-30 compliance, and no bridge or strain gauge excitation. If the requirement is power quality, this is the wrong instrument. If the requirement is stable, accurate, multi-point temperature and low-level electrical logging, it is the right one.
Yes, entirely. Setup, scanning, charting, statistics and alarms all run from the front panel, and the display charts up to four channels live with a history mode to scroll back through the scan file. Data goes to internal memory (20 MB, 57,000 scans, 1,000 setup files) or straight to a USB flash drive, including one-key .jpg screen captures for reports. For remote work, LAN with SCPI, the embedded web server, and Fluke DAQ software are available.
/20, /40 and /60 differ only in how many relay boards and Universal Input Connectors are installed — one, two or three — giving 22, 44 or 66 usable channels. All three can be expanded later with the 2638A-20chkit. The /C option adds an ISO/IEC 17025 accredited calibration certificate instead of the standard traceable factory report with data. Order /C if the instrument goes into a quality system that requires an accredited certificate; skip it if a traceable report with data is acceptable.