Fluke 922/KIT Airflow Meter - Differential Pressure & Pitot Tube Airflow Tester for HVAC Balancing

Fluke 922/KIT Airflow Meter - Differential Pressure & Pitot Tube Airflow Tester for HVAC Balancing

  • Highlight

    Fluke 922 airflow meter kit

    ,

    differential pressure airflow tester

    ,

    HVAC balancing pitot tube meter

  • Pressure Range
    ±4000 Pa (±16 In H2O / ±40 Mbar), 1 Pa Resolution
  • Air Velocity Range
    1 To 80 M/s (250 To 16,000 Fpm) Via Pitot Tube
  • Air Flow Range
    0 To 99,999 Cfm / M3/hr / L/s, User-defined Duct Shape
  • Measurement Modes
    Pressure (differential And Static), Velocity, Flow Volume
  • Kit Contents
    12 In Pitot Tube, ToolPak, Two Hoses, Hard Carrying Case
  • Protection And Power
    IP40, EN 61326-1, 4 X AA, 375 H Without Backlight
  • Shipping Term
    International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/Sea Freight / Air Freight / International Special Line
  • Freight Charge
    For Industrial Equipment (E.G., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/Volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quot
  • Brand Name
    Fluke
  • Model Number
    Fluke 922/922KIT
  • Minimum Order Quantity
    1
  • Price
    $900-1,249
  • Packaging Details
    Original
  • Delivery Time
    3-5Workdays
  • Payment Terms
    L/C,D/A,D/P,T/T

Fluke 922/KIT Airflow Meter - Differential Pressure & Pitot Tube Airflow Tester for HVAC Balancing

Product Highlights
  • Three instruments in one housing. Differential pressure, static pressure, air velocity and volumetric flow from a single micromanometer.
  • ±4000 Pa bi-directional pressure with 1 Pa resolution and ±1 % + 1 Pa accuracy — enough headroom for filter loading, coil drop and building pressurisation work.
  • 1 to 80 m/s velocity via pitot tube. Compatible with most pitot tubes, so a duct traverse gives a true average rather than a single spot reading.
  • Flow to 99,999 cfm, m³/hr or l/s, computed from a duct shape and dimensions you define on the meter.
  • User-defined duct shape and size is the accuracy lever on this instrument — enter the actual cross-section and the flow maths follows.
  • Coloured hoses so you can see at a glance which port is which when you are upside down in a plant room.
  • IP40 rated, MIL-PREF-28800F Class 3 vibration, 2,000 m operating altitude.
  • 99 stored readings with Min/Max/Average/Hold.
  • 375 hours on four AA cells without the backlight, 80 hours with it.
  • Kit version adds the 12 in pitot tube, ToolPak hanger and a hard carrying case — a complete traverse setup in one box.
Specifications
Measurement Ranges & Accuracy
Function Range Resolution Accuracy
Air pressure ±4000 Pa / ±16 in H₂O / ±400 mm H₂O / ±40 mbar / ±0.6 PSI 1 Pa / 0.001 in H₂O / 0.1 mm H₂O / 0.01 mbar / 0.0001 PSI ±1 % + 1 Pa / ±1 % + 0.01 in H₂O / ±1 % + 0.1 mm H₂O / ±1 % + 0.01 mbar / ±1 % + 0.0001 PSI
Air velocity 1 to 80 m/s (250 to 16,000 fpm) 0.001 m/s (1 fpm) ±2.5 % of reading at 2000 fpm (10.00 m/s)
Air flow 0 to 99,999 cfm / m³/hr / l/s 1 cfm / 1 m³/hr / 1 l/s Function of velocity and duct size
Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C / 0.1 °F ±1 % + 2 °C (±1 % + 4 °F)
Fluke 922 vs. Fluke 922/KIT
Parameter Fluke 922 Fluke 922/KIT
Measurement
Air pressure range ±4000 Pa (±16 in H₂O / ±40 mbar) ±4000 Pa (±16 in H₂O / ±40 mbar)
Pressure resolution 1 Pa 1 Pa
Pressure accuracy ±1 % + 1 Pa ±1 % + 1 Pa
Air velocity range 1 to 80 m/s (250 to 16,000 fpm) 1 to 80 m/s (250 to 16,000 fpm)
Velocity resolution 0.001 m/s 0.001 m/s
Velocity accuracy ±2.5 % of reading at 10.00 m/s ±2.5 % of reading at 10.00 m/s
Air flow range 0 to 99,999 cfm / m³/hr / l/s 0 to 99,999 cfm / m³/hr / l/s
Temperature range 0 to 50 °C (32 to 122 °F) 0 to 50 °C (32 to 122 °F)
Temperature accuracy ±1 % + 2 °C ±1 % + 2 °C
Instrument
Ingress protection IP40 IP40
Stored readings 99 99
Power and battery life 4 × AA, 375 h (80 h with backlight) 4 × AA, 375 h (80 h with backlight)
Warranty 2 years 2 years
Package Contents
12 in pitot tube Not included Included
ToolPak hanger Not included Included
Two rubber hoses Included Included
Wrist strap Included Included
Four AA batteries Included Included
User's manual Included Included
Carrying case Soft case Hard case
Optional add-on PT12 pitot tube, 12 in —
Fluke 922 / 922 KIT vs. Fluke 923
Feature Fluke 922 / 922 KIT Fluke 923
Sensing principle Pitot tube on a pressure port Hot-wire thermal probe
Velocity range 1 to 80 m/s 0.20 to 20.00 m/s
Pressure measurement Yes, ±4000 Pa differential and static No — barometric pressure is an entered setting only
Temperature range 0 to 50 °C −20 to 60 °C
Stored readings 99 198 (99 velocity + 99 flow)
Ingress protection IP40 Not stated
Best at Duct traverses, filter and coil drop, building pressure Low-speed air at grilles, hoods and cleanroom FFUs
Applications
  • Filter and coil pressure drop — the classic use: measure across a filter bank to decide whether it is loaded, or across a coil to confirm it is not fouling.
  • HVAC commissioning and air balancing (TAB) — duct traverses with a pitot tube for a proper average velocity, then computed flow.
  • Building pressurisation and envelope management — indoor versus outdoor pressure relationships, and stack-effect investigation.
  • Room-to-room pressure differential — cleanrooms, isolation rooms, laboratories and pharmaceutical suites where a defined cascade must be proven.
  • Fume hood and extraction verification — static pressure and face velocity checks on hoods and local exhaust.
  • Fan and air handler performance — total and static pressure across a fan to check it against its curve.
  • Duct leakage and tightness work — pressure decay and static pressure survey.
  • Indoor air quality investigations — ventilation rate against occupancy load.
  • Commissioning documentation — 99 stored readings for a walk-round, recalled at the clipboard.
Frequently Asked Questions
Q1. Should I buy the 922 or the 923?

Buy the 922 if the job involves pressure. Buy the 923 if it involves slow air in tight spaces. These are different instruments, not trim levels. The 922 is a micromanometer that derives velocity from a pitot tube, so it also reads differential and static pressure — which is what filter drop, coil drop and room pressurisation work actually requires. The 923 is a hot-wire anemometer: it reads from 0.20 m/s and its slim probe fits grilles and FFU faces, but it has no pressure sensor at all. Many contractors end up with both, because neither covers the other's job.

Q2. Does the 922 measure velocity without a pitot tube?

No — velocity comes from the pitot tube. The meter measures pressure at its ports; velocity is calculated from the velocity pressure the pitot generates. That is why the /KIT version exists: it bundles the 12 in pitot tube, the ToolPak hanger and a hard case, so the instrument is usable the day it arrives. Buying the bare 922 and sourcing a pitot separately is possible — it is compatible with most pitot tubes — but you will still need the hoses and somewhere to store them.

Q3. What is the actual airflow accuracy?

Fluke states it as a function of velocity and duct size, not a single percentage. That is not evasion — flow is velocity multiplied by cross-sectional area, so any error in your duct measurement propagates straight into the flow figure. It is why the meter asks you to enter duct shape and dimensions rather than assuming a round duct. Enter the real dimensions and the flow number is only as good as your tape measure and your traverse.

Q4. Can it handle building pressurisation work?

Yes — ±4000 Pa is comfortable for that. Typical building pressure targets sit in the tens of pascals, and severe stack-effect or fan-driven cases rarely exceed a few hundred pascals. The 1 Pa resolution matters more than the range here, and the bi-directional channel means a reversed reading shows as a negative number rather than needing the hoses swapped.

Q5. Battery life and power?

Four AA cells. 375 hours without the backlight, 80 hours with it. The backlight cuts runtime by roughly four-fifths, which is worth knowing before a long commissioning week — use it only when the plant room is actually dark. Auto power off is included.

Q6. Is it certified and what is the warranty?

IP40, EMC to EN 61326-1, MIL-PREF-28800F Class 3 vibration, two-year warranty. IP40 means protection against solid objects over 1 mm and no liquid protection — this is an indoor instrument, so do not leave it in the rain or on a wet roof. The datasheet states EN 61326-1 EMC conformance.