| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| Air velocity, m/s | 0.20 to 20.00 m/s | 0.01 m/s | ±5 % + 3 digits of reading, or ±1 % + 1 digit of full scale |
| Air velocity, fpm | 40 to 3940 fpm | 1 fpm | ±5 % + 6 digits of reading, or ±1 % + 1 digit of full scale |
| Air flow | 0 to 99,999 m³/hr, cfm, l/s | 0.001 to 100 | Function of velocity and duct size |
| Air temperature | -20 °C to 60 °C (-4 °F to 140 °F) | 0.1 °C / 0.1 °F | ±0.5 °C from 0 °C to 45 °C |
| Air temperature | — | — | ±1.0 °C from -20 °C to 0 °C and 45 °C to 60 °C |
| Air temperature, °F | — | — | ±1.0 °F from 32 °F to 113 °F; ±2.0 °F from -4 °F to 32 °F and 113 °F to 140 °F |
No — it lets you enter it.
This is the single most misquoted point about this model. Barometric pressure is a required input setting (shown in mmHg, defaulting to sea level) that the meter uses to compensate the velocity calculation. There is no pressure sensor, no pressure port and no differential pressure reading. If a job needs actual pressure measurement, that is a different instrument — the Fluke 922 airflow meter.
Hot-wire for slow air in small spaces; vane for fast air in large openings.
The 923's range starts at 0.20 m/s because a thermal sensor resolves air movement that would not turn a vane at all. That makes it the right tool for FFUs, hood faces and slot diffusers. A vane meter covers higher speeds and larger ducts more cheaply, but it reads nothing useful below roughly 0.4 m/s.
Two links, automatically selected.
With the probe seated on the meter body, the two halves talk over infrared. Lift the probe off and it switches to radio frequency, indicated by a flashing wireless symbol. If the RF link does not establish, reseat the probe and power cycle the meter — the manual's own remedy.
±5 % of reading + 3 digits, or ±1 % of full scale + 1 digit.
The percentage-of-full-scale clause is what protects low speeds: it caps the error band instead of letting a percentage-of-reading term balloon as the value approaches zero. Add 0.1 × accuracy for each degree outside 18 to 28 °C.
Two different types — 3 × AAA in the base, 1 × 9 V in the probe.
The probe is battery-powered precisely because it detaches. Fluke does not publish a runtime figure for this model, so carry spares rather than planning around a number. The meter also has separate low-battery indicators for base and probe, so watch both.
Meter, detachable telescopic probe, probe sensor cover, protective case, batteries and manual. Two-year Fluke warranty.