Product Details

Place of Origin: USA

Certification: UL/cUL/CE/UKCA/RoHS/FCC ABS/DNV GL

Model Number: CPE305、CPE310、CPE330、CPU315、CPU320

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $163- $8900

Delivery Time: 3-5workdays

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Chat Now
Highlight:

Emerson RX3i PLC migration

,

GE Fanuc 90-30 PLC replacement

,

industrial control PLC with warranty

Type:
Programmable Logic Controller
Warranty:
Original Manufacturer's Warranty
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/sea Freight / Air Freight / International Special Line
Freight Charge:
For Industrial Equipment (e.g., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quote
Type:
Programmable Logic Controller
Warranty:
Original Manufacturer's Warranty
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/sea Freight / Air Freight / International Special Line
Freight Charge:
For Industrial Equipment (e.g., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quote
In Stock RX3i PLC – Seamless Migration from GE Fanuc 90-30/90-70 Series
The RX3i PLC is a modular programmable automation controller belonging to Emerson's PACSystems portfolio, designed as a seamless upgrade replacement for the legacy GE Fanuc 90-30/90-70 series, with instant stock availability for global industrial buyers.
It offers direct compatibility with GE Fanuc 90-30/90-70 I/O modules, eliminating the need for rewiring during system transitions. By leveraging Proficy Machine Edition software, firmware from legacy systems can be migrated to the RX3i platform in as little as two hours, significantly cutting down the time and costs associated with equipment upgrades. Equipped with a high-speed multi-core processor, it supports diverse industrial protocols including PROFINET and OPC UA, and features a highly reliable redundant architecture. Boasting certifications such as ATEX and marine approvals (ABS/BV/LR), the RX3i PLC is well-suited for critical applications across energy, petrochemical, offshore engineering and other demanding industrial scenarios, making the ideal choice for upgrading legacy GE Fanuc systems to Industry 4.0 standards.
Core Product Features
  • Seamless Legacy System Migration: Directly compatible with GE Fanuc 90-30/90-70 I/O modules; no rewiring required during upgrades. Firmware migration via Proficy Machine Edition software can be completed in as little as 2 hours, minimizing production downtime and replacement costs.
  • High-Performance Processing & Scalability: Equipped with multi-core high-speed processors, supporting up to 32k discrete I/O points and 32k analog I/O words. User memory ranges from 6MB to 64MB with flexible expansion capabilities.
  • Rich Multi-Protocol Communication Capabilities: Supports mainstream industrial protocols including PROFINET, OPC UA, Modbus TCP/IP, SRTP, and EGD. Integrates 10/100/1000Mbps Ethernet ports for fast data transmission.
  • High Availability Redundant Design: Features redundant architecture for key components, supporting 3ms frame rate redundancy and OPC UA transparent server redundancy. Hot-swappable module design allows on-site maintenance without system shutdown.
  • Diversified Certification & Harsh Environment Adaptation: Holds multiple international certifications including UL/cUL, CE, ATEX Zone 2, UL HazLoc C1D2, and marine certifications (ABS/BV/LR). Optional conformal coating models resist high humidity, corrosion, and extreme temperatures.
  • Edge Computing & Security Functions: Advanced models integrate PaceEdge Linux technology, supporting edge computing to process data locally. Built-in TPM security modules and encrypted communication protect industrial data.
  • Cost-Effective & Easy Maintenance: Compatible with existing GE Fanuc system programming habits, reducing learning costs. Abundant global stock ensures fast delivery with professional technical support.
Key Selling Points
  • Zero-disruption Legacy Upgrade: Directly compatible with GE Fanuc 90-30/90-70 I/O modules and firmware. No rewiring or major program adjustments needed—migrations completed in 2 hours maximum.
  • Multi-certified for Harsh Scenarios: Boasts ATEX Zone 2, UL HazLoc C1D2, and ABS/BV/LR marine certifications. Optional conformal coating models resist humidity, corrosion, and extreme temperatures.
  • High-Availability Redundant Architecture: Supports 3ms frame rate redundancy and OPC UA transparent server redundancy. Hot-swappable modules enable on-site maintenance without production line shutdown.
  • Industry 4.0-Ready Connectivity: Integrates multi-core processors and 10/100/1000Mbps Ethernet ports, supporting PROFINET, OPC UA, Modbus TCP/IP, and other mainstream protocols.
  • Global Stock & Fast Deployment: Abundant in-stock supply worldwide with fast delivery for international projects. Professional technical support for migration, debugging, and after-sales service.
Technology Parameters
Parameter Category Parameter Item CPE305 CPE310 CPE330 CPU315 CPU320/CRU320
Processor Microprocessor 1GHz AMD Z510PT Silverthrone XL 1GHz Intel Atom Z510PT Silverthrone XL 1GHz AMD G-Series Dual Core Soc GX-209HA 1GHz Intel Celeron M Atom 1.1GHz Intel Celeron M Atom
User Memory 5MB 10MB 64MB 20MB 64MB
Memory Program Memory (Battery-Backed RAM) 5MB 10MB 64MB 20MB 64MB
I/O Capacity Discrete I/O Points 32K bits 32K bits 32K bits 32K bits 32K bits
Analog I/O Words 32K words 32K words 32K words 32K words 32K words
Communication Interfaces Ethernet Ports 10/100Mbps x1 (Built-in or via ETM001) 3x 10/100/1000Mbps (2 switched ports) 3x 10/100/1000Mbps (2 switched ports) 10/100/1000Mbps x1 10/100/1000Mbps x1
USB Interfaces USB-A 1.1 x1 USB-A 2.0 x1 USB-A 2.0 x1 USB-A 2.0 x1 USB-A 2.0 x1
Serial Ports RJ-25 conn x1 (RS-232)
15-pin D-conn x1 (RS-485)
9-pin D-conn x1 (RS-232)
15-pin D-conn x1 (RS-485)
9-pin D-conn x1 (RS-232)
15-pin D-conn x1 (RS-485)
9-pin D-conn x1 (RS-232)
15-pin D-conn x1 (RS-485)
9-pin D-conn x1 (RS-232)
15-pin D-conn x1 (RS-485)
Redundancy Support Redundancy Type - Media Redundancy (MRP) (Requires PNC001) Media Redundancy (MRP), PROFINET System Redundancy (PNSR) - -
Environmental Adaptability Operating Temperature 0℃~60℃ 0℃~60℃ 0℃~60℃ 0℃~60℃ 0℃~60℃
Certifications Industrial Certifications UL/cUL, CE, ATEX Zone 2, UL HazLoc C1D2 UKCA, UL, cUL, ATEX Zone 2, UL HazLoc C1D2 UKCA, UL, cUL, ATEX Zone 2, UL HazLoc C1D2 - -
Marine Certifications - ABS, BV, LR, DNV GL ABS, BV, LR, DNV GL - -
Product Models
Product Type Model Core Specifications Overseas Adaptation Highlights
CPU Units IC695CPE305 6MB user memory, 32k discrete I/O points, 32k analog I/O words, 2x 10/100/1000Mbps switched Ethernet ports Includes Energy Pack, supports MRP media redundancy, marine certifications (ABS/BV/LR), ideal for offshore engineering scenarios
IC695CPE310 13MB user memory, 3x 10/100/1000Mbps Ethernet ports (2 switched), supports 255 simplex remote I/O devices Multi-core high-speed processor, PROFINET plug-and-play, mainstream model for manufacturers in India and Southeast Asia
IC695CPE330 64MB user memory, 32k discrete I/O points, 32k analog I/O words, 3x 10/100/1000Mbps Ethernet ports Supports OPC UA transparent server redundancy, preferred for European and American energy projects, UL HazLoc C1D2 certified
IC695CPK400 (CPE400) 1.2GHz AMD quad-core processor, VXWORKS OS, built-in TPM security module, OLED display Includes Energy Pack, supports 3ms frame rate redundancy, EU ATEX Zone 2 certified, adapted to chemical industry
IC695CPL410 Quad-core processor, built-in PaceEdge Linux technology, 1Gbps Ethernet, supports OPC UA/Modbus TCP Open-source edge computing capability, adapted to European and American smart factories, supports FTP(S)/HTTP(S) encrypted communication
Power Supply Modules IC695PSD040 24VDC input (18-30VDC wide voltage range), 40W total load, 0-60℃ operating temperature UL/CE/ATEX certified, optional conformal coating (model: IC695PSD040CA), adapted to high-temperature environments in the Middle East
Communication Modules IC695PNS001 PROFINET scanner module, hot-swappable design, supports high-speed I/O update (8ms/16 devices) Compliant with European industrial bus standards, commonly used in German automotive production lines
IC695ETM001 Ethernet communication module, supports SRTP/Modbus TCP/IP/EGD, 10/100Mbps speed Mainstream selection for North American factory automation, FCC certified compliant
RX3i IEC 61850 Dedicated for power system communication, supports IEC 61850 client/server protocols Adapted to European and American power grid/substation projects, compatible with DNP3/iec-104 protocols
I/O Modules RX3i DC24V 32-point Input 32-point discrete input (24VDC), optional response time, channel-isolated design Adapted to Southeast Asian electronic manufacturing lines, UL/cUL certified
RX3i AC/DC 16-point Input 16-point universal input (24VAC/DC), 15m transmission distance, surge protection Commonly used in European food packaging lines, dual UKCA/CE certification
RX3i 4-point 24VDC Output 4-point discrete output (24VDC), 2.0A/point, positive/negative logic selectable, RSTi-EP series Adapted to North American warehousing equipment, supports 2/3/4-wire wiring
Functional Modules RX3i High-Speed Counter Module Multi-channel high-speed counting, supports incremental encoder/pulse input, isolated design Adapted to German automotive parts processing lines, strong anti-interference capability
RX3i Thermocouple Input Module Multi-channel TC/RTD input (K/J/PT100, etc.), channel-to-channel isolation, 0.1℃ resolution Temperature monitoring in Nordic chemical parks, wide operating temperature range (0-60℃)
Industry Applications
  • Offshore Engineering & Marine Equipment: Drilling platform control, ship power distribution, cargo handling system automation in the North Sea, Gulf of Mexico, and Southeast Asian coastal waters. Marine certifications (ABS/BV/LR) and corrosion-resistant conformal coating models withstand salt spray, high humidity, and vibration.
  • Petrochemical & Hazardous Chemical Plants: Pipeline flow control, tank level monitoring, and reactor temperature regulation in Middle Eastern oil refineries and European chemical parks. UL HazLoc C1D2 and ATEX Zone 2 certifications meet explosion-proof requirements with hot-swappable modules for maintenance without shutdown.
  • Power Grid & Energy Infrastructure: Substation automation, wind turbine control systems in Nordic wind farms, and solar power plant energy management in North America. Supports IEC 61850 power system protocol for seamless integration with grid equipment.
  • Automotive Manufacturing Lines: Assembly line robot control, welding process automation, and quality inspection data collection in German and Mexican automotive factories. PROFINET compatibility enables fast communication with Siemens robots and other European-made equipment.
  • Warehouse & Logistics Automation: Automated storage and retrieval system (AS/RS) control, conveyor belt speed regulation in Amazon overseas warehouses and European e-commerce distribution centers. Multi-protocol support connects with WMS for real-time inventory tracking.
  • Mining & Heavy Machinery: Mine hoist control, ore crusher automation in Australian iron ore mines and African copper mines. Wide operating temperature range (0~60℃) adapts to extreme mine environments with strong anti-interference capability.
Frequently Asked Questions
Q1: Why does the RX3i show "corrupt user memory" fault after power outage in Middle Eastern petrochemical plants?
This is almost always caused by poor grounding or electrical interference in harsh industrial environments. In Saudi Arabian refineries, we've found that ungrounded AC power supplies and nearby high-voltage pipelines are the main culprits. Fix it by using isolating transformers for the PLC's AC power supply to filter electrical noise, routing PLC signal cables in shielded trunking at least 1 meter away from high-voltage lines, and replacing PLCs over 10 years old as old CPUs lack ECC memory for error correction.
Q2: The PROFINET communication drops frequently in German automotive factories when connecting RX3i to Siemens robots, what's wrong?
It's usually a firmware mismatch or incorrect rack configuration, not the hardware itself. German auto plants often mix RX3i with legacy GE Fanuc 90-30 modules, which causes PROFINET conflicts. Try cross-checking the firmware version in Proficy Machine Edition with Emerson's compatibility matrix, avoiding "auto-config" for remote I/O racks with analog modules, and ensuring the RX3i rack's BEM331 module is revision K or higher.
Q3: In Nordic wind farms, the RX3i's I/O modules overheat and trigger false alarms, how to solve this?
Nordic wind farms have high humidity and tight control cabinet spaces, leading to poor heat dissipation. On-site fixes from Danish wind farm engineers include using a thermal camera to scan the I/O rack and replace any terminal blocks with temperatures over 60℃, disabling unused I/O channels via the RX3i's built-in settings to reduce power load, and installing small axial fans in the control cabinet to circulate air around the modules.
Q4: The redundant CRU320 system has mismatched DI variables between primary and secondary controllers in Australian mining sites, why?
This is a common mistake in redundant system setup—most miners forget to configure the "transfer list" for data sharing. The fix is simple: in Proficy Machine Edition, go to the CPU's hardware configuration and open the "transfer list" tab to add all DI/DO variables to the shared list, and ensure the primary and secondary controllers use the same IP address for Ethernet synchronization.
Q5: In Southeast Asian marine platforms, the RX3i's Ethernet port loses connection after salt spray exposure, even with marine certifications?
Marine certifications (ABS/BV) cover the main unit, but the RJ45 Ethernet ports are vulnerable to salt corrosion. Singaporean offshore engineers use these workarounds: replace the standard RJ45 cables with waterproof SFP fiber modules for the RX3i's Ethernet ports, apply anti-corrosion conformal coating to the Ethernet port pins, and avoid mounting the RX3i rack near the platform's saltwater cooling system.
Q6: The RX3i's SCADA communication fails in Mexican warehouses, but the PLC itself runs normally, what's the issue?
Mexican warehouses often use cheap radio modems for wireless communication, which disrupt the Ethernet reference address of the RX3i's CPU. Fix it by checking the "Eth. Ref. Address" in the CPU's diagnostics, toggling the read/write status bits in the ladder logic to refresh the SCADA connection, and using Modbus TCP/IP instead of SRTP for warehouse WMS integration as Modbus is more stable with low-cost wireless modems.