Shanghai Fradwell Industrial Automation Co., Ltd.
cnsales@fradwell.com 86-21-68060766
Products
Products
Home > Products > Industrial Automation Control Systems > S7-1500 PLC Programmable Logic Controllers Industrial PLC Controller

S7-1500 PLC Programmable Logic Controllers Industrial PLC Controller

Product Details

Place of Origin: Germany

Certification: CE UL UKCA RCM KC EAC ATEX/IECEx SIPLUS RoHS REACH FM KCC

Model Number: CPU 1511 1513 1516 1516F 1517F 1518F 1511C 1512C

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: USD170-4000

Delivery Time: 3-5workdays

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Chat Now
Highlight:

S7-1500 PLC Programmable Logic Controllers

,

S7-1500 Industrial PLC Controller

,

Programmable Logic Controllers Industrial

Type:
CPU
Pakage:
Original Pakage
Warranty:
Original Manufacturer's Warranty
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/sea Freight / Air Freight / International Special Line
Freight Charge:
For Industrial Equipment (e.g., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quote
Type:
CPU
Pakage:
Original Pakage
Warranty:
Original Manufacturer's Warranty
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/sea Freight / Air Freight / International Special Line
Freight Charge:
For Industrial Equipment (e.g., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quote
S7-1500 PLC Programmable Logic Controllers Industrial PLC Controller
High Cost-Effectiveness + Long Lifespan – S7-1500 PLC Becomes the Preferred Investment for Overseas Industrial Automation
S7-1500 PLC: High-Performance Industrial Automation Solution
The S7-1500 series PLC represents a high-end modular programmable logic controller designed for global medium-to-large industrial automation projects. As the upgraded replacement for the S7-300/400 series, it features an all-new hardware architecture and high-performance processor with instruction execution speeds several times faster than its predecessors. This controller supports high-precision motion control for up to 32 axes, complex process control, and distributed safety control, with flexible working memory expansion exceeding 20MB to meet demanding large-scale data processing and intensive control tasks.
Core Features & Technical Highlights
Extreme Performance: High-Speed Computing & Flexible Expansion
  • Industry-leading computing speed: Bit operation instruction processing time as low as 1ns, floating-point operations in just 64ns
  • High-speed backplane bus with point-to-point response time less than 500μs
  • Modular design supports flexible expansion: Up to 32 modules per rack with maximum 8192 I/O points
  • Multiple performance-grade CPUs covering standard, compact, fail-safe, motion control, and MFP versions
Integrated Process Functions: Comprehensive Control Solution
  • Native motion control integration supporting up to 20 speed control axes, positioning axes, and external encoders
  • PLCopen standard instructions for high-precision multi-axis synchronization and electronic cam control
  • Built-in PID controller with auto-tuning for complex process regulation scenarios
  • Standard TRACE function across all CPUs for quick troubleshooting and performance optimization
Intelligent Connectivity: Digital Transformation & IoT Ready
  • Each CPU integrates 1-3 PROFINET interfaces supporting PROFINET IRT real-time communication
  • Compatible with multiple industrial protocols including PROFIBUS, Modbus TCP, and more
  • Built-in OPC UA server/client for direct cloud platform connectivity
  • Backward compatible with S7-300/400 modules and programs via TIA Portal migration tools
Comprehensive Safety Assurance
  • Fail-safe CPUs compliant with IEC 61508 SIL 3/PL e standards
  • Runs standard and safety programs on the same controller
  • Built-in industrial cybersecurity features including secure boot and firmware digital signatures
  • Program copy protection with four-level permission management
Technical Specifications
Core Performance Specifications of Standard CPUs
Parameter Type CPU 1511-1PN CPU 1513-1PN CPU 1515-2PN CPU 1516-3PN/DP CPU 1518-4PN/DP
Order Number 6ES7 511-1AK00-0AB0 6ES7 513-1AL00-0AB0 6ES7 515-2AM00-0AB0 6ES7 516-3AN00-0AB0 6ES7 518-4AP00-0AB0
Program Work Memory 150KB 300KB 500KB 1MB 4MB
Data Work Memory 1MB 1.5MB 3MB 5MB 20MB
Bit Instruction Execution Time 60ns 40ns 30ns 10ns 1ns
Maximum Positioning Axes 10 10 30 30 128
Industry Applications & Practical Scenarios
Automotive Manufacturing & New Energy Vehicle Industry
Core control solution for leading automakers and component suppliers, particularly suited for high-end production lines and new energy projects. Applications include welding workshop control, battery module production, and engine block machining lines with real-time data synchronization and precision control.
Petrochemical & Oil & Gas Extraction Industry
Preferred safety control solution for high-risk environments including onshore oilfields and offshore platforms. Features SIL 3-certified safety I/O modules for gas concentration monitoring, pressure control, and emergency shutdown systems in hazardous material storage areas.
Energy & Energy Storage Industry
Comprehensive coverage for thermal power, wind power, and energy storage sectors with emphasis on stability and data collaboration. Includes redundant systems for critical power plant control and extreme environment variants for wind farm applications.
Frequently Asked Questions
Q: We're migrating an old S7-300 project to S7-1500 in our US factory, but the original FB/FC blocks can't be directly imported into TIA Portal. How to fix this?
A: Use TIA Portal's built-in "Migration Tool". Save the S7-300 project as a Step7 V5.6 file, then open TIA Portal and go to "Project > Migrate" to select the file. Most ladder logic blocks convert automatically, though some PROFIBUS/Profinet configuration blocks may require reworking.
Q: Our S7-1500 CPU 1516-3PN/DP keeps losing connection with Allen-Bradley VFDs via Modbus TCP. The communication drops randomly every 2-3 hours. Any solutions?
A: This is typically a timeout or data mapping issue. Increase the "Response Timeout" from the default 1s to 3s in TIA Portal's Modbus TCP configuration. Check data length limits and enable "Keep-Alive" packets to prevent connection closures.
Q: We need to install S7-1500 in a North Sea offshore platform (ATEX Zone 1). Does the standard S7-1500 meet explosion-proof requirements?
A: No, standard S7-1500 isn't ATEX-certified. You need the SIPLUS extreme variant rated for Zone 1/21 with IECEx/ATEX certifications, plus resistance to salt fog, vibration, and extreme temperatures.