Product Details

Place of Origin: Japan

Model Number: W1000

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $200 - $2500

Delivery Time: 3-5Workday

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Chat Now
Highlight:

water pump inverter W1000

,

frequency inverter for water pumps

,

W1000 inverter with warranty

Product Name:
Frequency Converte Inverter
Voltage Classes:
3-Phase 380V-480V
Rated Power:
0.75kW - 355kW
Warranty:
Original Factory Warranty
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
Product Name:
Frequency Converte Inverter
Voltage Classes:
3-Phase 380V-480V
Rated Power:
0.75kW - 355kW
Warranty:
Original Factory Warranty
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
W1000 Inverter for Water Pump Applications
W1000 Inverter for Water Pump Applications
Advanced inverter solution designed specifically for water pump applications, featuring energy-saving control technology for efficient operation with both induction motors (IM) and synchronous motors (SM). The silent control function automatically reduces voltage during low-speed or light-load operation, delivering low-noise and energy-efficient performance.
Core Features
Energy Efficiency & Dual-Motor Compatibility
  • Dedicated Energy-Saving Control Technology for both Induction Motors (IM) and Synchronous Motors (SM)
  • Automatic voltage optimization under low-speed or light-load conditions
  • 10%-30% improved energy efficiency compared to standard inverters
  • Synchronous motor driving eliminates rotor copper loss, lowers bearing temperature, and extends motor lifespan
Multi-Pump Intelligent Control
  • Fixed Variable-Speed Pump Mode: 1 variable-speed pump + up to 3 constant-speed pumps (expandable to 11 with optional DO-A3 card)
  • Rotation Switch Mode 1: Cycle variable-speed control for up to 5 pumps (requires DO-A3 card)
  • Rotation Switch Mode 2: Cycle variable-speed control for up to 3 pumps (expandable to 11 with optional DO-A3 card)
Low-Noise Operation & Environmental Adaptability
  • Swing PWM switching technology minimizes electromagnetic interference and operating noise
  • Moisture and dust resistance design compliant with RoHS environmental directives
  • Suitable for harsh environments including outdoor pump rooms and basements
High-Precision Control & Stable Performance
  • High-precision torque limitation (±5% error) under vector control
  • High-speed response above 50Hz with PG feedback control
  • Adjustable acceleration/deceleration time (0.1-3600s)
  • S-curve characteristic switching to prevent water hammer and pipeline vibration
Safety & Long-Life Design
  • Compliant with EN954-1 Cat.3 and IEC/EN61508 SIL2 safety standards
  • EDM (External Device Monitoring) function for real-time safety circuit monitoring
  • 10-year inverter design life with built-in wear part life diagnosis
  • KEB (Kinetic Energy Backup) function for rapid motor shutdown during power outages
Easy Maintenance & Expandability
  • Detachable terminal block with parameter backup function
  • Standard RS-422/485 communication interface
  • Support for PROFIBUS-DP, DeviceNet, CC-Link, and other fieldbuses
  • Compatible with DriveWorksEZ visual programming and DriveWizard Plus debugging tools
Key Technical Specifications
Category Specifications Notes
Input Power 3-Phase 380V-480V ±10%, 50/60Hz Compatible with global mainstream industrial power grids
Rated Output Power 0.75kW - 355kW Models: CIMR-EB4W0002 (0.75kW) to CIMR-EB4W0675 (355kW)
Rated Output Current 2.1A (0.75kW) - 675A (355kW) Refer to factory selection manual for specific values
Output Frequency Range 0.01Hz - 600Hz Meets high-speed pump operation requirements
Control Mode V/F Control, Sensorless Vector Control, Vector Control with PG Torque control accuracy ±5% (with PG vector mode)
Frequency Accuracy Digital: ±0.01%; Analog: ±0.2% Ensures stable constant-pressure water supply
Braking Function Built-in brake transistor, supports over-excitation braking Heavy-duty models require optional brake unit
Protection Functions Overcurrent, Overload, Overvoltage, Undervoltage, Overheating, Phase Loss, Torque Limitation Comprehensive protection for pumps and inverters
Environmental Adaptability Temperature: -10℃~+45℃; Humidity: 20%~90%RH Custom high/low temperature versions available
Protection Class IP20 (standard), optional IP54 High-protection version for outdoor installation
Certifications CE, UL/cUL, RoHS, SIL2 Complies with EU/US market access requirements
Typical Applications
  • Municipal water supply systems and sewage treatment plants
  • Industrial cooling water circulation and central air conditioning systems
  • Secondary water supply for high-rise buildings and community constant-pressure water supply
  • Agricultural irrigation and water conservancy project pump stations
  • Corrosion-resistant pumps in chemical and pharmaceutical industries
Model Information
Model Naming Convention
Model Component Meaning Example
CIMR- Yaskawa Inverter Universal Prefix CIMR-
EB4W Series Identifier (W1000 Water Pump-Specific, 380-480V 3-Phase) EB4W
00XX Capacity Code (Corresponding to Rated Output Power) 0002 (for 0.75kW)
Suffix (Optional) -HT: High-Temperature Version; -IP54: High-Protection Version CIMR-EB4W0018-HT
Core Model Specifications
Model Rated Power Rated Current Motor Type Overload Capacity Protection Class Certifications
CIMR-EB4W0002 0.75kW 2.1A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0004 1.5kW 4.1A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0005 2.2kW 5.4A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0007 3.0kW 6.9A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0009 3.7kW 8.8A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0011 5.5kW 11.1A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
CIMR-EB4W0018 7.5kW 17.0A IM/SM 150% 60s IP20/IP54 CE, UL/cUL, RoHS, SIL2
Additional models available up to 355kW - contact for complete specifications
Selection Notes for Overseas Markets
  • Voltage Matching: Compatible with global industrial power grids (380-480V 3-Phase, 50/60Hz)
  • Certification Adaptation: CE for European market, UL/cUL for North America
  • Load Adaptation: Reserve 20% power margin for heavy-load scenarios
  • Accessory Matching: Recommended brake units for high-power models (≥45kW)
Frequently Asked Questions
Q1: Pressure fluctuations during low water demand in European municipal projects?
Adjust Pr.144 (PI Proportional Gain) to 3.0 and Pr.145 (PI Integral Time) to 15.0s. Enable Pr.575 (Sleep/Wake Function) with sleep threshold at 80% of rated pressure. This reduces pressure fluctuation to ±0.1 bar.
Q2: Overheating faults in Southeast Asian sewage treatment plants?
Clean heat sink and fan filter every 2 weeks with compressed air. Install additional axial fan (150m³/h) in electrical cabinet for improved air circulation. Avoid installation near sewage pump to reduce humidity exposure.
Q3: Pressure drop during pump switching in multi-pump systems?
Set Pr.A21 (Multi-Pump Pre-Excitation Time) to 0.5s and Pr.A22 (Pre-Excitation Torque) to 10%. This preloads torque to standby pump before valve opens, reducing switching delay to 0.3 seconds.
Q4: Derating in high-temperature Middle Eastern environments?
Install inverter vertically, add sunshade cover to electrical cabinet, and set Pr.73 (Overload Protection Level) to 120% 60s. For permanent solution, upgrade to -HT high-temperature model (operates up to 55℃).
Q5: Communication issues with Siemens PLC in German chemical plants?
Use optional PROFIBUS-DP/Profinet card (SI-P1). Set Profinet Device Name to match PLC configuration and map pressure data to Process Data Object (PDO). Use shielded CAT5e or higher cable to prevent interference.
Q6: Parameter recovery without damaged terminal block?
Use USB drive with DriveWizard Plus software via front USB port, or use RS-485 cable to copy parameters from another W1000 in same system using Pr.970 (Parameter Copy) function.
Q7: Rust issues in seawater desalination applications?
Upgrade to IP54 high-protection model with corrosion-resistant coating. Temporary solution: apply marine-grade anti-corrosion spray and install dehumidifier in cabinet.
Q8: Overcurrent faults during fire pump startup?
Change control mode to "V/f control" (Pr.79 to 1), increase acceleration time to 5.0s (Pr.71), and enable Pr.250 (Fire Pump Mode). Check for stuck impeller causing high startup load.