Product Details

Place of Origin: France

Model Number: ATV212

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $200 - $4000

Delivery Time: 3-5Workday

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Chat Now
Highlight:

75kW Frequency Inverter 480V

,

ATV212 Frequency Inverter

,

3 Phase Variable Frequency Drive

Product Name:
Frequency Converter Inverter
Output Power:
0.75–75kW
Level Of Protection:
IP21 /IP55
Warranty:
Original Factory Warranty
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
Product Name:
Frequency Converter Inverter
Output Power:
0.75–75kW
Level Of Protection:
IP21 /IP55
Warranty:
Original Factory Warranty
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
ATV212 0.75–75kW Frequency Inverter 480V 3 Phase Variable Frequency Drive

ATV212 Industry-specific frequency converters 0.75–75kW Frequency Inverter for Fans and Pumps

ATV212 Industry-Specific Frequency Converters 0.75–75kW
The Altivar 212 frequency inverter is an intelligent, low-harmonic, high-performance HVAC-specific device designed for pumps, fans, and compressors. Suitable for 0.75 kW to 75 kW three-phase induction motors, it is specifically engineered for fluid management applications in tertiary industry buildings (HVAC), including heating, ventilation, air conditioning, and pumping. With eco-energy design, it can achieve energy savings of up to 70% compared to traditional control systems.
Technical Specifications
Parameter Category Specification
Motor Compatibility 0.75 kW - 75 kW three-phase induction motors
Voltage Ratings 200...240V three-phase (0.75-30kW)
380...480V three-phase (0.75-75kW)
Protection Class IP 21, UL Type 12/IP 55 (depending on model)
Speed Range 1:50
Instantaneous Overtorque 110% - 60 seconds
Harmonic Suppression THDI < 30%
EMC Filter Integrated EMC filter, Class C1 to C3
Communication Protocols Modbus, METASYS N2®, APOGEE FLN P1®, BACnet®
Optional: LonWorks
Certifications UL, CSA, C-Tick, NOM
Core Application Scenarios
Building Ventilation Systems
  • Compatible with various ventilation equipment, reducing hydraulic and motor noise pollution
  • Supports detection of transmission component damage and smoke extraction fault protection
  • Features automatic restart (30 times) and register management functions
  • Ideal for commercial buildings and public venues
Heating & Air Conditioning Systems
  • Precisely regulates temperature, flow rate and pressure through PID controllers
  • Adjustable fluid flow rate enables energy-saving management
  • Suppresses mechanical resonance to extend equipment service life
  • Suitable for shopping malls, office buildings, hotels and other facilities
Pump Equipment Operation Control
  • Targets various pumps including water supply and circulating pumps
  • Supports underload/overload and dry pump operation detection
  • Compatible with multi-motor configuration
  • Features low-speed operation time limit and sleep/wake functions
General Building Fluid Management
  • Supports decentralized technology management and building monitoring networks
  • Equipped with building-specific functions including fire mode and mechanical protection
  • Optimizes equipment operation through preventive maintenance features
Available Models
Model Series Specific Models Core Parameters
HD Series (IP21 protection) ATV212HD11N4, ATV212HD15N4, ATV212HD18N4, ATV212HD22N4, ATV212HD30N4, ATV212HD37N4, ATV212HD45N4, ATV212HD55N4, ATV212HD75N4 Power: 11kW-75kW, built-in EMC filter
HU Series (380-500V wide voltage) ATV212HU30N4, ATV212HU40N4, ATV212HU55N4, ATV212HU75N4, ATV212HU075N4 Power: 7.5kW-75kW, supports multiple building communication buses
WD Series (UL Type 12/IP55) ATV212WD11N4, ATV212WD15N4, ATV212WD18N4, ATV212WD22N4, ATV212WD30N4, ATV212WD37N4, ATV212WD45N4, ATV212WD55N4, ATV212WD75N4 Power: 11kW-75kW, EMC Class C2 filter
WU Series (IP55 protection) ATV212WU15N4, ATV212WU22N4, ATV212WU30N4 Power: 15kW-30kW+, suitable for harsh environments
Basic small-power models ATV212W075N4, ATV212W075N4C Power: 0.75kW
Frequently Asked Questions
How to choose the right model without wasting?
Check the rated power of your pump or fan motor (marked on the machine). Choose an ATV212 model with the same power or slightly higher. For example, a 0.75kW fan pairs with ATV212W075N4; a 30kW pump works with HD30N4 or WD30N4 (choose WD series for outdoor use).
Will the inverter break if installed outdoors or in humid places?
For ordinary indoor areas, the IP21 HD/HU series is sufficient. For outdoor, dusty, or humid locations, select the UL Type 12/IP55 protection WD/WU series, which has better waterproof and dustproof performance.
How to adjust parameters during use?
Use the supporting remote panel or SoMove software to adjust maximum speed by entering desired values directly. For automatic temperature/pressure control, set PID parameters easily—the inverter adjusts speed automatically without manual monitoring.
Can it connect to existing control systems?
The ATV212 comes with Modbus protocol as standard, supported by most common control systems. For BMS systems requiring BACnet® or LonWorks, choose the corresponding optional protocol version when purchasing.
What if it suddenly shuts down during operation?
Common causes include overload (pump jamming, fan blades stuck), phase failure (poor wire contact), or dry pump operation. Cut power, check for jams, clean debris, check terminal blocks, or add water before restarting. The built-in protection function prevents burnout.