Shanghai Fradwell Industrial Automation Co., Ltd.
cnsales@fradwell.com 86-21-68060766
Products
Products
Home > Products > Drives & Motion Control > Altivar Process Series ATV600 Variable Frequency Drive for general applications, with a power range of 0.75 kW to 800 kW.

Altivar Process Series ATV600 Variable Frequency Drive for general applications, with a power range of 0.75 kW to 800 kW.

Product Details

Place of Origin: Japan

Model Number: ATV600

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: $400 - $3000

Delivery Time: 3-5Workday

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Chat Now
Highlight:

Altivar Process ATV600 variable frequency drive

,

ATV600 drive with 0.75-800kW power range

,

general purpose variable frequency inverter

Output Power:
0.75 KW-2600 KW
Level Of Protection:
IP20/IP21 IP55/IP54
Warranty:
Original Factory Warranty
Product Name:
Frequency Converter Inverter
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
Output Power:
0.75 KW-2600 KW
Level Of Protection:
IP20/IP21 IP55/IP54
Warranty:
Original Factory Warranty
Product Name:
Frequency Converter Inverter
Pakage:
Original Pakage
Shipping Term:
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
Altivar Process Series ATV600 Variable Frequency Drive for general applications, with a power range of 0.75 kW to 800 kW.
Altivar Process ATV600 Variable Frequency Drive
The Altivar Process Series ATV600 Variable Frequency Drive is designed for general applications with a comprehensive power range from 0.75kW to 2600kW, offering versatile motor control solutions for industrial environments.
Product Overview
The Altivar 600 series inverter is available in three configurations: wall-mounted standalone units, cabinet-mounted modular standalone units, and complete variable frequency drive systems. It supports various motor types including synchronous motors and is widely implemented in standard load control applications. The series complies with international standards including IEC/EN 61800-3, IEC/EN 61000-4, IEC/EN 60721-3, and IEC/EN 61800-5-1.
Supporting multiple voltage levels across a broad power spectrum, the ATV600 delivers consistent user experience while balancing practicality, functionality, performance, and flexibility.
Wall Mounting Configuration
Basic Specifications
Product Type Altivar Process ATV600 wall-mounted ready-to-use inverter
Applicable Motor Types Induction motors, permanent magnet motors, reluctance motors; compatible with IE2 - IE4 efficiency class motors
Control Mode Open-loop control
Power Range
Overall Power Coverage: 0.75kW - 315kW (1HP - 500HP) for wall-mounted configuration
  • 380 - 480V voltage: IP20/21/UL Type 1 rated 0.75kW - 315kW; IP55 rated 0.75kW - 90kW
  • 500 - 690V voltage: IP20/21/UL Type 1 rated 2.2kW - 90kW
  • 200 - 240V voltage: Compatible with 2.2kW (4HP, standard load) and 3kW (3HP, heavy load)
Voltage Range
Three-phase Voltage Coverage: 200 - 240V, 380 - 480V, 500 - 690V
Voltage Fluctuation Tolerance: ±15%~±10% for 200 - 240V and 380 - 480V voltage classes
Electrical Performance
Harmonic Index (THDI) THDI < 48% with built-in configuration; THDI < 10% or < 5% when paired with passive filters or multi-pulse power supplies; THDI ≤ 3% with low-harmonic modules
Transient Current 1.1x rated current for 60 seconds (standard load); 1.5x rated current for 60 seconds (heavy load)
Insulation Resistance >1MΩ (tested with 500V DC, 1 minute to ground)
Communication Configuration
Built-in Interfaces: 3 RJ45 communication ports, 1 Ethernet port, 2 serial ports
Basic Protocols: Ethernet, Modbus
Optional Extended Protocols: Ethernet/IP, Modbus TCP, CANopen, Profinet, Profibus DP V1, etc.
Safety & Functions
  • Safety Functions: Supports STO (Safe Torque Off) function, compliant with SIL3 safety level
  • Embedded Features: Pump efficiency tracking, multi-master-slave pump management, pump pipe protection, fan management
  • Energy consumption measurement accuracy >95%
  • Standby Energy Saving: Innovative "start-stop" operation mode, saving 30% energy in standby state
Floor-standing Configuration
Basic Specifications
Product Model Altivar Process ATV600 Series Floor-standing Inverter
Applicable Motor Types Three-phase induction motors, permanent magnet synchronous motors, synchronous reluctance motors; compatible with IE2 - IE4 efficiency class motors
Control Modes Open-loop control; asynchronous motors support standard constant torque, standard variable torque, and optimized torque modes
Power & Voltage Parameters
Power Coverage: 0.75kW - 2600kW (full voltage range); common floor-standing power segment: 2.2kW - 2600kW
Voltage Range: Three-phase 200 - 240V, 380 - 480V, 500 - 690V
Supply Frequency: 50 - 60Hz, allowing ±5% fluctuation
Electrical Performance
Current Parameters For 37kW model, line current at 380V (standard load) is approximately 67.4A (heavy load), and at 480V (standard load) is approximately 59.1A
Transient Current 1.1x rated current for 60 seconds (standard load); 1.5x rated current for 60 seconds (heavy load)
Harmonic Index THDI < 48% with built-in configuration; THDI < 10% or 5% when paired with passive filters or multi-pulse power supplies; THDI ≤ 3% with low-harmonic modules
Safety & Energy-saving Functions
  • Safety Functions: Supports STO (Safe Torque Off) function, compliant with SIL3 safety level
  • Protection Functions: Built-in multiple protections including electronic overload, short circuit, phase loss, ground fault, DC bus overvoltage/undervoltage, equipment overheating
  • Energy-saving Features: Innovative "start-stop" operation mode, saving up to 30% energy in standby state
Application Fields
The ATV600 inverter specializes in fluid transportation and gas handling equipment requiring speed regulation and energy efficiency optimization:
  • Water and wastewater treatment: Compatible with centrifugal pumps, submersible sewage pumps, pipeline pumps for municipal water supply, sewage treatment, and reclaimed water reuse
  • Building automation: Matched with central air conditioning circulating pumps, building water supply pumps, underground garage fans, fire pressure maintenance pumps
  • Food and beverage processing: Driving screw pumps, diaphragm pumps for conveying sauces and fruit juices, food drying fans, and packaging compressors
  • General industrial sector: Suitable for centrifugal pumps, positive displacement pumps, general fans, and industrial compressors across chemical, power, and manufacturing applications
Technical Support & Troubleshooting
Q: When driving a centrifugal pump, the ATV600 frequently reports "Overcurrent Fault (OC)" at startup despite correct motor wiring. What could be the cause?
A: This is typically due to improper startup parameter settings. Centrifugal pumps face high fluid resistance during startup. Extend the acceleration time to 15-20 seconds and moderately increase low-speed torque. Also verify the motor's rated current falls within the inverter's output current range.
Q: In building water supply systems with constant pressure control, water pressure fluctuates constantly with frequent inverter starts/stops. How to resolve?
A: Optimize PID parameters and start/stop thresholds. Check pressure feedback signal stability, adjust proportional gain (start with P=5.0) and integral time (I=100 seconds), then expand sleep thresholds to avoid frequent cycling from minor pressure fluctuations.
Q: The inverter controls a fan and reports "Overheating Fault (OH)" after running, though ambient temperature is normal and fan isn't locked. What's the issue?
A: Check for blocked inverter heat dissipation channels or mismatched fan parameters. Verify cooling fan operation and clean dust from heat sinks. Switch to fan-specific V/F curve and adjust overload protection level from 150% to 110%.
Q: Motor speed fluctuates during screw pump operation with "frequency fluctuation" displayed, though fixed frequency is set. How to troubleshoot?
A: Check for signal interference and wiring issues. Use shielded control wires separated from power wires by at least 30cm. Test with fixed frequency set directly on the inverter panel to isolate external setpoint circuit problems.
Q: After six months of use, the ATV600 reports "Communication Fault (COMM)" and cannot be controlled remotely via PLC. How to fix?
A: Verify communication parameters and physical connections. Check that communication address and baud rate match PLC settings. Inspect RS485 wires for proper connection and oxidation. Restore default communication parameters and rematch with PLC.
Q: When driving a compressor, the inverter frequently reports "Overload Fault (OL)" though discharge pressure is normal and motor current doesn't exceed rated value. What's the reason?
A: The load type may be set incorrectly or carrier frequency too high. Switch to constant torque V/F curve and reduce carrier frequency from 8kHz to 4-6kHz. Also check if compressor startup pressure is too high.
Q: In humid sewage treatment environments, the ATV600 occasionally reports "Ground Fault (GF)" but works normally after power cycling. How to resolve completely?
A: Improve moisture and insulation protection. Use IP54 or higher protection level, install moisture-proof boxes or dehumidifiers. Check motor and cable insulation with megohmmeter. Lower ground fault detection sensitivity from 50% to 30% to avoid false alarms.