Product Details
Place of Origin: Switzerland
Model Number: ACS510
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: $500 - $12000
Delivery Time: 3-5Workday
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
|
Product Name:
|
Frequency Converter Inverter
|
Rated Power:
|
1.1 - 160kW
|
Level Of Protection:
|
IP21 IP54
|
Warranty:
|
Original Factory Warranty
|
Pakage:
|
Original Pakage
|
Shipping Term:
|
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
|
|
Product Name:
|
Frequency Converter Inverter
|
|
Rated Power:
|
1.1 - 160kW
|
|
Level Of Protection:
|
IP21 IP54
|
|
Warranty:
|
Original Factory Warranty
|
|
Pakage:
|
Original Pakage
|
|
Shipping Term:
|
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/ Sea Freight / Air Freight / International Special Line
|
| Parameter Category | Specific Parameters | Details |
|---|---|---|
| Power Range | Rated Power | 1.1 - 160kW (1.5 - 215hp) |
| Voltage Specifications | Input Voltage | Three-phase 380-480V AC±10%; Single-phase 230V AC±10% (1.1-2.2kW models) |
| Control Functions | Control Modes | V/F Control (fan/pump optimized), PID Closed-Loop Control |
| Control Functions | Speed Regulation Range | 0.5 - 50Hz (fans); 0.5 - 60Hz (pumps) |
| Control Functions | PID Regulation Accuracy | ±0.5% |
| Communication Interfaces | Standard Interface | Modbus RTU (RS-485) |
| Communication Interfaces | Optional Interfaces | PROFIBUS DP, DeviceNet, EtherNet/IP |
| Structure & Protection | Protection Class | Standard: IP21; Optional: IP54 protective enclosure |
| Structure & Protection | Installation Method | Cabinet-mounted, Wall-mounted (IP54 models) |
| Environmental Adaptability | Operating Temperature | -10℃ - 50℃ (derated operation up to 60℃) |
| Environmental Adaptability | Anti-Interference Design | Standard Class C3 EMC filter, compliant with EN 61800-3 |
| Energy-Saving Features | Core Energy-Saving Functions | Fan/pump optimized V/F curve, Sleep/Wake-up function, High-voltage drop operation mode |
| Protection Functions | Core Protection Functions | Overcurrent, Overvoltage, Overheating, Phase loss, Motor overload, PID feedback loss protection |
| Model | Rated Output Current (A) | Rated Motor Power (kW) | Rated Motor Power (hp) | Input Voltage Range | Frame Size | Application Scenarios |
|---|---|---|---|---|---|---|
| ACS510-01-01A6-4 | 1.6 | 1.1 | 1.5 | 380-480V AC±10% | R1 | Small cooling fans, laboratory ventilation fans |
| ACS510-01-02A4-4 | 2.4 | 1.5 | 2 | 380-480V AC±10% | R1 | Small constant pressure water supply pumps, office fresh air fans |
| ACS510-01-03A3-4 | 3.3 | 2.2 | 3 | 380-480V AC±10% | R1 | Medium ventilation fans, small irrigation pumps |
| ACS510-01-04A1-4 | 4.1 | 3 | 4 | 380-480V AC±10% | R1 | Industrial cooling water pumps, sewage treatment aeration pumps |
| ACS510-01-05A6-4 | 5.6 | 4 | 5.5 | 380-480V AC±10% | R2 | Medium constant pressure water supply pumps, shopping mall air conditioning fans |
| ACS510-01-07A2-4 | 7.2 | 5.5 | 7.5 | 380-480V AC±10% | R2 | Subway tunnel ventilation fans, industrial boiler induced draft fans |
| ACS510-01-09A4-4 | 9.4 | 7.5 | 10 | 380-480V AC±10% | R2 | Large cooling fans, farm irrigation pumps |
| ACS510-01-12A6-4 | 12.6 | 11 | 15 | 380-480V AC±10% | R3 | Large constant pressure water supply systems, high-speed rail station fresh air fans |
| ACS510-01-17A0-4 | 17.0 | 15 | 20 | 380-480V AC±10% | R3 | Industrial circulation water pumps, sewage treatment plant aerators |
| ACS510-01-25A0-4 | 25.0 | 18.5 | 25 | 380-480V AC±10% | R3 | Large ventilation fans, high-pressure water supply pumps |
| ACS510-01-31A0-4 | 31.0 | 22 | 30 | 380-480V AC±10% | R4 | Industrial boiler induced draft fans, large irrigation pump stations |
| ACS510-01-43A0-4 | 43.0 | 30 | 40 | 380-480V AC±10% | R4 | Municipal sewage treatment aerators, large central air conditioning fans |
| ACS510-01-59A0-4 | 59.0 | 45 | 60 | 380-480V AC±10% | R5 | Large industrial cooling systems, urban water supply booster pump stations |
| ACS510-01-72A0-4 | 72.0 | 55 | 75 | 380-480V AC±10% | R5 | Subway tunnel main ventilation fans, large sewage treatment plants |
| ACS510-01-92A0-4 | 92.0 | 75 | 100 | 380-480V AC±10% | R6 | Industrial large fans, ultra-high pressure water supply pumps |
| ACS510-01-125A0-4 | 125.0 | 90 | 125 | 380-480V AC±10% | R6 | Large industrial circulation systems, urban water supply main pipe booster |
| ACS510-01-155A0-4 | 155.0 | 110 | 150 | 380-480V AC±10% | R7 | Ultra-large ventilation fans, large sewage treatment plant aerators |
| ACS510-01-180A0-4 | 180.0 | 132 | 175 | 380-480V AC±10% | R7 | Industrial giant cooling fans, urban water supply hub pump stations |
| ACS510-01-210A0-4 | 210.0 | 160 | 215 | 380-480V AC±10% | R8 | Ultra-large industrial fluid systems, large tunnel ventilation projects |
| Industry | Application Scenarios | Key Advantages |
|---|---|---|
| Municipal Water Supply/Wastewater Treatment | Constant pressure water supply systems, sewage treatment aeration fans, tap water booster pump stations | Precise PID regulation, significant energy savings, global spare parts availability, 24/7 continuous operation capability |
| HVAC Systems | Central air conditioning fans in commercial buildings, hotel hot water circulation pumps, industrial plant ventilation systems | Building automation system integration, low-noise operation (≤60dB), compliance with indoor environmental standards |
| Transportation Infrastructure | Subway tunnel ventilation fans, high-speed rail station fresh air systems, airport de-icing pumps | Wide voltage adaptation, high protection class, resistance to humid and dusty tunnel environments |
| Industrial Manufacturing | Industrial cooling fans, boiler induced draft fans, production line circulation pumps | Strong overload capacity (110% rated load for 60 seconds), adaptation to high-frequency start-stop and harsh conditions |
| Agricultural Irrigation | Large farm irrigation pumps, orchard drip irrigation booster systems | Wide temperature tolerance (-10℃ - 50℃), energy-saving features reducing electricity costs, outdoor installation suitability |