Detail Produk
Tempat asal: Perancis
Sertifikasi: F1/E2/C2
Syarat Pembayaran & Pengiriman
Kuantitas min Order: 1
Harga: $5,500 - $48,000+ (Based on kVA rating and voltage)
Waktu pengiriman: 3-5 hari kerja
Syarat-syarat pembayaran: L/C,D/A,D/P,T/T,Western Union
|
Teknologi Isolasi:
|
Resin Cor (Terbungkus)
|
Kelas Perilaku Kebakaran:
|
F1 (Pemadaman otomatis)
|
Kelas Lingkungan:
|
E2 (Tahan terhadap polusi/kondensasi)
|
Kelas Iklim:
|
C2 (Tahan terhadap guncangan termal)
|
Pelepasan parsial:
|
< 10 pC (Isolasi bermutu tinggi)
|
Kepatuhan standar:
|
IEC 60076-11 / EN 60076-11
|
Jangka Waktu Pengiriman:
|
Ekspres Internasional(DHL/FEDEX/TNT/UPS/ARAMEX)/Pengangkutan Laut / Pengangkutan Udara / Jalur Khusu
|
Biaya Pengiriman:
|
Untuk Peralatan Industri (misalnya Modul PLC, Inverter..), Biaya Pengiriman Bervariasi Berdasarkan B
|
|
Teknologi Isolasi:
|
Resin Cor (Terbungkus)
|
|
Kelas Perilaku Kebakaran:
|
F1 (Pemadaman otomatis)
|
|
Kelas Lingkungan:
|
E2 (Tahan terhadap polusi/kondensasi)
|
|
Kelas Iklim:
|
C2 (Tahan terhadap guncangan termal)
|
|
Pelepasan parsial:
|
< 10 pC (Isolasi bermutu tinggi)
|
|
Kepatuhan standar:
|
IEC 60076-11 / EN 60076-11
|
|
Jangka Waktu Pengiriman:
|
Ekspres Internasional(DHL/FEDEX/TNT/UPS/ARAMEX)/Pengangkutan Laut / Pengangkutan Udara / Jalur Khusu
|
|
Biaya Pengiriman:
|
Untuk Peralatan Industri (misalnya Modul PLC, Inverter..), Biaya Pengiriman Bervariasi Berdasarkan B
|
| Model | Rated Power | Voltage Ratio | Vector Group | Impedance |
|---|---|---|---|---|
| Trihal 250kVA | 250 kVA | 10(20)/0.4 kV | Dyn11 / Yzn11 | 4.0% |
| Trihal 630kVA | 630 kVA | 10(20)/0.4 kV | Dyn11 | 4.0% / 6.0% |
| Trihal 1000kVA | 1000 kVA | 10(20)/0.4 kV | Dyn11 | 6.0% |
| Trihal 1600kVA | 1600 kVA | 10/0.4 kV | Dyn11 | 6.0% |
| Trihal 2500kVA | 2500 kVA | 35/0.4 kV | Dyn11 | 6.0% / 7.0% |
| Trihal 3150kVA | 3150 kVA | 35/0.415 kV | Dyn11 | 7.0% / 8.0% |
Trihal is oil-free, eliminating fire and leakage risks, making it ideal for indoor infrastructure like hospitals and data centers.
It guarantees the transformer is self-extinguishing and produces no toxic gases during a fire, ensuring maximum safety for high-occupancy buildings.
No. Its cast resin design is virtually maintenance-free, only requiring occasional cleaning of the cooling air channels.
Yes, with its C2 climatic rating, it can operate in temperatures as low as -25°C and handle sudden, heavy load changes.
Yes, the E2 rating ensures reliable performance in environments with high humidity or heavy pollution without track-mark risks.
We offer Natural Air (AN) as standard and Forced Air (AF) to increase power capacity by up to 40% when needed.